Skip to main content

Hitachi

Hitachi Home AppliancesMalaysia

RAS-VX10CJ New

Premium Inverter Series (R32)

Features

Fresh Air, Healthy Life

Frost Wash Freezes the Heat Exchanger, Melts &
Washes Away the Dust by Sensor.

*Tested by Kitasato Research Center of Environmental Science. Effect when operating Frost Wash manually 4 times.

more info ButtonMore Info

Play Video ButtonPlay Video

Dust & Bacteria Removal Frost Wash

Generate Plenty of Water*1, Step1:Freeze, Step2:Melt & Wash, Step3:Dry *Fan Operation only.Generate Plenty of Water*1, Step1:Freeze, Step2:Melt & Wash, Step3:Dry *Fan Operation only.

*1 Create larger amount of water compared to normal cooling operation.

Long Lasting Hygiene Air

Clean Air, Wash away dust, mold, oily grime, and other causes of odors.

Without Frost Wash

Without Frost Wash

With Frost Wash

With Frost Wash

93%*2 Bacteria Reduction,93%*2 Mold Reduction

*2 Tested by Kitasato Research Center of Environmental Science.

Easy Maintenance

Frost Wash will periodically operate when your absence is detected by sensor. Or you can launch Frost Wash manually.

Human SensorHuman Sensor

Auto Frost Wash

Frost WashFrost Wash

Manual Frost Wash

Fresh Air from Clean Root

1. Keep Water & Air Pathway Clean

STAINLESS CLEAN System Hitachi Original

Antibacterial stainless steel is applied inside to keep the air pathways extra hygienic for fresh, healthy, clean air.

Stainless Air Duct, Stainless Louvre, Stainless Dew Plate, Nano Titanium Stainless Pre-Filter, Frost Wash, 99% Antibacterial*3, 50% Dust Cut*4 Stainless Air Duct, Stainless Louvre, Stainless Dew Plate, Nano Titanium Stainless Pre-Filter, Frost Wash, 99% Antibacterial*3, 50% Dust Cut*4

2. Room Air Purification

Stainless Pre-Filter, Nano Titanium Wasabi Air Purifying Filter, UV FreshStainless Pre-Filter, Nano Titanium Wasabi Air Purifying Filter, UV Fresh

Effect

99% Antibacterial*5

95% Anti-Allergen*6

82% Odor Removal*7

98% Violate Organic Compounds Suppression*7

Mold Suppression*7

Tested by: *3 Boken Quality Evaluation Institute *4 The Hitachi Environmental Test Laboratory *5 University Putra Malaysia *6 International Medical University Malaysia *7 Nanopac Testing Lab.

Close

Automatic Comfort Day & Night

2 Cameras Monitor Human and Room
Condition to Best Support Your Comfort.

more info ButtonMore Info

Play Video ButtonPlay Video

Automated Night Time Comfort Air Sleep Feel / SCENE CAMERA CEILINGAir Sleep Feel / Scene Camera Ceiling

Ideal Temperature & Humidity Balance for Sleep. 19dB* Silence for Good Sleep.

Nice and Chilly Dive into Sleep., Silent & Comfort Environment for Deep Sleep., Refreshing Awakening With Cool Breeze.Nice and Chilly Dive into Sleep., Silent & Comfort Environment for Deep Sleep., Refreshing Awakening With Cool Breeze.

*Min. operation noise of 1.0HP and 1.5HP Air Sleep Feel models. When humidity control is on, operating noise & temperature may slightly increase depending on the humidity condition.

Ideal Air Flow Control

Scene Camera enables a targeted air flow towards heated areas, for example a hot person rolling over, or towards the ceiling.

Human Targeted Flow

Human Targeted Flow

Ceiling Flow

Day Time Comfort Welcome Breeze

Welcome with Extra Cold air target blown when You come home.

Detects Human LocationDetects Human Location

Auto-shift to Heat source Cooling for Fast & Even Cooling after 15 min.

Blow Longer Time, Blow Shorter Time

Close

Smart Energy Saving

2 Cameras and Inverter Technology realize 62%
Energy Saving*.

*Hitachi 1.5HP Scene Camera Ceiling Model (Eco Mode) compared with a 1.5HP non-inverter model (Cooling Mode).

more info ButtonMore Info

Play Video ButtonPlay Video

Smart Energy Saving

Eco Mode

Automatically adjusts cooling operation for energy saving.

SCENE CAMERA CEILING

When 3 People are Together

Comfort Cooling

When Only 1 Person Remains in the Room

Soft Cooling

When No One is in the Room

Auto Save

10 min of absence

Auto Off

1h of absence

Auto On

When people come back

  • If you leave the air conditioner operating when you are not at home, please cancel the Auto Off setting. Do not use the Auto Off setting in rooms occupied by people who cannot operate the air conditioner themselves such as infants, children, the elderly and individuals who are ill or physically impaired.

VECTOR DC INVERTER

Achieves top class energy saving and cooling capacity.

Non-Inverter Normal Cooling, VECTOR DC INVERTER Eco Mode, Energy Saving 62%*1Non-Inverter Normal Cooling, VECTOR DC INVERTER Eco Mode, Energy Saving 62%*1

*1 RAS-VX13CJT (Eco Mode) compared with a Hitachi 1.5HP non-inverter model (Cooling Mode). Power consumption based on cumulative power consumption after 8 hours of operation. Room temperature at start: 35°C, Set temperature: 25°C, Fan Speed: Auto.
Testing condition: Three people in the room. Level of activity at 2.5m from the indoor unit estimated to be 1.0 metabolic equivalents (reading, etc.). Three people in separate locations in the room during the daytime with the curtains closed to cut the amount of sunlight to a low level. Ambient temperature lower than the set temperature.

Close

Reliable & Durable

Vector DC Inverter realizes Energy Saving &
Reliable Operation.

more info ButtonMore Info

Play Video ButtonPlay Video

Reliable Operation

Instantaneous Power Failure / Voltage Fluctuation: Non-Stop Cooling Operation.

Power Black Out: Auto Restart at Previous Setting.

Reliable OperationHitachi Original

Instantaneous Power Failure: Non-Stop Operation

If there’s an instantaneous power failure (sudden voltage fluctuation), the Vector DC System detects the voltage fluctuation to prevent the air conditioner from stopping due to a current surge.

Case1, Huge Drop of Voltage, Stable Operation

Power Failure: Auto Restart at Previous Setting

If there’s a power blackout, a microcomputer in the Vector DC System memorizes the setting at the time of the blackout, and automatically restarts operation at the same setting after power recovery.

Case2, Memorizes Operation Setting Before Power Failure., Auto Restart

Durability

Fireproof Electrical Enclosure

100% metal housing tightly seal the electrical components to ensure safety.

Indoor Unit
Outdoor Unit Anticorrosion Paint

Anti-Rust, Anti-Corrosion Coating

Anti-Rust coating is applied for the outdoor unit casing. Anti-Corrosion coating is applied for the condenser.

Anti-Rust Outdoor Casing
Green-Fin Condenser

Close

Tech Spec

Energy Star Rating (Meps Label)
Meps Label (star) : ★★★★★
SIRIM REFERENCE : 17.30 Btu/hr.W (2017EEA1123)
Power Consumption / year : 1238 kWh/yr.
Model
Indoor: RAS-VX10CJ 
Outdoor: RAC-VX10CJ
Phase, Voltage, Frequency
1Ø,220-230V, 50Hz
Cooling Capacity
2.85 (0.90-3.50)kW
9730 (3070-12000)BTU/h
EER
15.00BTU/h.W
COP
4.40
Total Input
648 (210-1190)W
Total Amperes
3.40-3.25A
Airflow Volume
12.0/11.5/9.0/6.0/3.5㎥/min
(Powerful/H/M/L/Silent)
Indoor Sound Level
48/44/35/27/19dB
(Powerful/H/M/L/Silent)
Outdoor Sound Level
51dB
Dehumidifying Capacity
1.6 l/h
Net Dimensions(W x H x D)
Indoor: 790×300×280mm
Outdoor: 750×570×280mm
Net Weight (Indoor/Outdoor)
11/32kg
Piping
Diameter (Liquid/Gas): 6.35/ 9.52mm
Maximum Length/ Height: 20/10m
Power Supply
Indoor
Refrigerant
R32
Key Feature
Scene Camera Ceiling
Air Sleep Ceiling
Air Sleep Feel
Eco Mode
Auto Save, Auto Off, Auto On
Welcome Breeze
Refresh Mode
Frost Wash
Stainless Clean
Stainless Dew Plate
UV Fresh
Nano Titanium WASABI Air Purifying Filter
Powerful Mode
19dB Silent Mode
Sensor Dry Operation
Direct/Indirect Swing
Up-Down, Left-Right Auto Swing
12-hr Timer
Vector DC Inverter
Auto Restart
Fireproof Electrical Enclosure
Anti-Corrosion Green Fin
Anti-Rust Outdoor Casing